Disclaimer: FOR TEST AND EXAMPLE PURPOSES ONLY! These web pages are not intended to be used as a source of information on medicines. The web pages are not kept up to date and are for demonstration purposes only. For up-to-date information on a medicine, please consult www.ema.europa.eu/medicines or the package leaflet of your medicine.
Show source BACK TO LIST

Laboratory Report

Patient
Name: Toscano, Abbondanzio
DOB: 04-JUL-1979 (Age: 46)
Gender: male
Address:
Via del Viminale 11
09033 Decimomannu (Italy)
ID: 2005-291300-9
Report
Date: 18-MAR-2025
Laboratory
dr Ample, Ex
Boulevard du Jardin Botanique 32
1000 Brussels
Requested by
Poliambulatorio ASL
(Italy)
Specimen
Collected: 17-MAR-2025

This seems not to be an HL7 Europe Laboratory Report (type coding LOINC 11502-2)

Chemistry

Test 17 Mar 2025 Reference Range Unit
Hemoglobin A1c/Hemoglobin.total in Blood 6.2 H 4 - 6 %

Annotation

Conclusion and Recommendations based on this report and previous findings known to us
The patient shows persistently elevated HbA1c, indicating suboptimal long-term glycemic control and possible diabetes or prediabetes. Creatinine is mildly elevated, suggesting possible early renal impairment. Other parameters, including electrolytes and glucose, are within normal limits. Recommend clinical follow-up for glycemic management and renal function monitoring.